Cryolite Ratio & Excess AlF₃ Calculator
Convert bath analysis (excess AlF₃, CaF₂, Al₂O₃) to cryolite ratio / bath ratio, and size the AlF₃ addition needed to reach a target ratio.
1. Bath analysis → ratios
Enter the bath analysis in weight %. Everything not listed is taken as cryolite (Na₃AlF₆).
2. Reach a target ratio
Uses the analysis entered on the left as the current bath.
Formulas: CR = 3m ÷ (m + 2.5·x); BR = CR ÷ 2; AlF₃ needed = 0.4·m·(3 − CRₜ) ÷ CRₜ − current excess AlF₃, with m = cryolite mass. 1 kg Na₂CO₃ neutralises ≈ 1.06 kg excess AlF₃ (3 Na₂CO₃ + 4 AlF₃ → 2 Na₃AlF₆ + Al₂O₃ + 3 CO₂). Molar masses: NaF 41.99, AlF₃ 83.98, Na₃AlF₆ 209.94 g/mol.
Products used with this calculation
Frequently asked questions
- What is the cryolite ratio (CR) of an aluminium smelting bath?
- The cryolite ratio is the molar ratio NaF : AlF₃ in the electrolyte. Pure cryolite (Na₃AlF₆) has CR = 3.0. Modern Hall–Héroult cells run acidic baths with excess AlF₃, typically CR 2.2–2.5 (about 8–13 wt% excess AlF₃), which lowers the liquidus temperature and improves current efficiency.
- What is the difference between cryolite ratio and bath ratio?
- Bath ratio (BR) is the same ratio expressed by weight (mass NaF ÷ mass AlF₃). Because the molar mass of AlF₃ (83.98 g/mol) is twice that of NaF (41.99 g/mol), BR = CR ÷ 2. CR 2.4 equals BR 1.20.
- How is excess AlF₃ converted to cryolite ratio?
- Per 100 kg of bath with x % excess AlF₃, c % CaF₂ and a % Al₂O₃, the cryolite fraction is m = 100 − x − c − a. Moles NaF = 3m/209.94 and moles AlF₃ = m/209.94 + x/83.98, so CR = 3m ÷ (m + 2.5x). Example: 10 % excess AlF₃, 5 % CaF₂, 3 % Al₂O₃ gives CR = 246 ÷ 107 = 2.30.
- How much AlF₃ must be added to lower the cryolite ratio?
- For a bath of mass M with cryolite mass m, the excess AlF₃ needed for a target ratio CRₜ is 0.4 × m × (3 − CRₜ) ÷ CRₜ. Subtract the excess AlF₃ already present to get the addition. The calculator does this and also converts a negative result into the soda-ash (Na₂CO₃) addition that raises the ratio instead.
- Does the calculator include LiF or MgF₂ additives?
- No. It treats the bath as cryolite + excess AlF₃ + CaF₂ + Al₂O₃, which covers most smelters. Lithium or magnesium fluoride additions change the NaF balance and should be handled by your plant's bath-chemistry model.
These calculators are provided free of charge for estimation. Verify results against your own plant data and procedures before acting on them. Ask our technical team if you need help.